Pickling and passivation of stainless steel flanges

Views : 320
Author : admin
Update time : 2025-07-31 09:30:40

  This method is suitable for stainless steel flanges and offers excellent results. Since the treated parts are fully immersed in the pickling and passivation solution, surface reaction occurs, resulting in a fine and uniform passivation film. This method is suitable for continuous and intermittent operation, but requires replenishment of the solution as the concentration decreases. However, its drawbacks are limited by the size and capacity of the acid tank, making it unsuitable for large-capacity equipment and excessively long and wide pipelines. Furthermore, it lacks the ability to minimize the effects of solution evaporation, requiring specialized installations, acid tanks, and heating equipment.

  Stainless steel pickling and passivation pastes are widely used in China, with a range of products available. Their main ingredients include nitric acid, hydrofluoric acid, corrosion inhibitors, and adhesives. The paste method is suitable for weld seam treatment, weld discoloration, deck tops, corners, the underside of escalators, and large-scale tank modifications and passivation. The advantages of the paste method are that it requires no special equipment or location, no heating equipment, flexible on-site operation, and completes pickling and passivation in one go, offering high independence. The passivation paste has a long shelf life, requiring a fresh coat of passivation for each treatment. After a layer of surface passivation, the reaction ceases, preventing excessive corrosion and unrestricted by subsequent flushing time. Passivation can also be applied to weak areas such as welds. However, its disadvantages include poor operating conditions, high labor intensity, high costs, and poor treatment results, necessitating the use of other methods.

  It is suitable for pickling and passivation of single products or equipment with simple internal structures in fixed locations and enclosed environments. Its advantages are rapid continuous operation, simplicity, minimal corrosion to workers, and the ability to pickle the pipes again during liquid transfer, resulting in higher solution utilization. However, this method has several limitations, including: all scaffolding within the tanks must be removed, the tanks and pipes must be clean, and there must be no residue or impurities in the pipes; all deep-well pumps, valves, tank cleaning machines, and other liquid cargo systems on board must be commissioned and ready for use; if the pickling solution remains in the tanks for too long, a reaction may occur, causing excessive corrosion of the stainless steel. Continuous operation is required, requiring the shipyard's close cooperation and the availability of sufficient clean water at all times. Power or water outages can have serious consequences; waste acid and wastewater should be discharged in larger containers or temporarily replaced in the cabins, but they must be neutralized and discharged as quickly as possible to avoid corrosion. As the reaction time and impurities in the solution increase, the useful components of the pickling solution gradually decrease, requiring constant monitoring of the solution concentration and the timely preparation of fresh solution. The spray solution also remains on decks, walls, blind spots, and the underside of escalators for a shorter period of time, resulting in slightly less effective pickling than on the floor.

  Pickling passivation pretreatment: If there is grease or other dirt on the surface of the stainless steel flange, it will affect the quality of pickling passivation. Generally speaking, the inner wall of the water tank should be cleaned with alkaline detergent. Control of chloride ion concentration in the pickling liquid/paste and cleaning water: If the chloride ion content exceeds the standard, it will damage the stainless steel passivation film. Some stainless steel pickling liquids/pastes use hydrochloric acid, a corrosive medium containing chloride ions, as the main agent or auxiliary agent to remove the surface oxide layer. It is unfavorable to avoid corrosion, so it is necessary to control it during inspection.

Related News
Read More >>
DIN 2576 PN10 Slip On Flange Dimensions DIN 2576 PN10 Slip On Flange Dimensions
Nov .19.2026
DIN 2576 PN10 slip on flange is one of our core forged products at Hebei Shengtian Pipe-fitting Group. Fabricated to DIN 2576 specification, this slip-on flange is rated PN10, ideal for low-pressure piping connections.
DIN 2573 PN6 Slip On Flange Dimensions DIN 2573 PN6 Slip On Flange Dimensions
Nov .17.2026
DIN 2573 PN6 Slip On Flange is a popular slip-on plate flange following the DIN 2573 standard for low-pressure piping applications, rated for a nominal working pressure of 6 bar.
DIN 2545 PN40 Slip On Flange Dimensions DIN 2545 PN40 Slip On Flange Dimensions
Nov .12.2026
Hebei Shengtian Pipe Fittings Group Co., Ltd. supplies premium DIN 2545 PN40 Slip On Flanges
DIN 2544 PN25 Slip On Flange Dimensions DIN 2544 PN25 Slip On Flange Dimensions
Nov .10.2026
DIN 2544 specifies slip-on flanges rated at PN 25 .Covers sizes DN 10 to DN 1000.The flanges with the dimensions of this standard can be used at maximum 120°C temperature with up to 25 bar of working pressure.